Design CriterionTechnical Parameters
Operating Temperature - PTFE ( TFM ) -40°C~150°C
Working Pressure - Refer to the Pressure Temperature curve chart on the right
Mode - Manual / Pneumatic
Control Unit - Feedback Device, Positioner, Cylindrical Position Sensor
Ball Seat Material - PTFE
Ball Valve Type Body - Full Port / Standard
Material - 316L (EN 1.4409/CF3M) (EN1.14404)
Interface Form - Weld Ends Type, Clamp Ends Type
Interface Diameter - 15~100
Surface Finish - External Surface Ra < 0.8μm
- Internal Surface Ra < 0.5μm
Specification Standard - DIN, ISO Standards, and 3A, CE certification
These valves can withstand temperatures up to 150℃with SIP (Steam-In-Place), but only when using PTFE sealing material and when the valve is fully open. Before operation, the temperature of any sealing material shall be below 95℃
When connecting two clamp ends, they can move axially by 30-40mm (depending on the specifications) for valve maintenance (refer to detailed instructions).